Error description
A loop in ERBCNFSR UA71999 + x'15C6' through x'1706' can occur when device x'FFFF' is defined. The loop index is defined as a half word field and when the highest device is x'FFFF', the index will wrap and the loop delimiter condition will never be met so the code continues to loop. The loop only occurs when device x'FFFF' is defined and one of the following ptfs is applied: UA72026, UA72027 or UA71999. If device x'FFFF' is not defined or the above ptfs are not applied, then there is no exposure to the problem.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: RMF Users * **************************************************************** * PROBLEM DESCRIPTION: RMF support for data * * gathering/reporting of PPRC Primary * * devices and the LCUs they belong to in * * subchannel set 1 or higher. * * SMF 74 subtype 1 and SMF 79 subtype 9 * * record is changed. * **************************************************************** * RECOMMENDATION: None please install this apar. * **************************************************************** With this APAR RMF provides support to report on PPRC Primary devices and LCUs, where the devices are situated in a subchannel set other than 0 in Monitor I, II and III. Additionally Control Unit Queuing Time is stored to SMF 74 subtype 1 and SMF 79 subtype 9 record. +--------------------------------------------------------------+ >>>>> SMF RECORD TYPE 70 TO 79 - RMF PRODUCT SECTION <<<<< The SMF record level change number SMFxxSRL at offset 51 (x33) changes to 105 (x68). >>>>> SMF RECORD TYPE 74 SUBTYPE 1 - DEVICE ACTIVITY <<<<< The Device data section is changed. OFFSET NAME LEN FORMAT DESCRIPTION ... 120 x78 SMF74CNX 1 Device flag extension Bit Meaning When Set 7 Device connected to FICON ... 176 xB0 SMF74CUQ 4 Control Unit Queuing Time 180 xB4 * 1 Reserved 181 xB5 SMF74SCS 1 Subchannel Set the device is situated 182 xB6 SMF74NM2 2 Device number same as SMF74NUM >>>>> SMF RECORD TYPE 79 SUBTYPE 9 - DEVICE ACTIVITY <<<<< The Device data section is changed. OFFSET NAME LEN FORMAT DESCRIPTION ... 108 x6C R799CUQ 4 Control Unit Queuing Time 112 x70 R799CN2 1 Device flag extension 2 Bit Meaning When Set 0 Device connected to FICON 113 x71 R799SCS 1 Subchannel set the device is situated 114 x72 R799NM2 2 Device number same as R799NUM Affected RMF releases: z/OS-1.12 up to z/OS 2.1 NOTE: For z/OS 2.1 this support is shipped by PTF for APAR OA42068.
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
OA44771
Reported component name
RMF
Reported component ID
566527404
Reported release
790
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-03-14
Closed date
2014-04-08
Last modified date
2014-05-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA73114 UA73115 UA73116
Modules/Macros
ERBCNFSR
Fix information
Fixed component name
RMF
Fixed component ID
566527404
Applicable component levels
R770 PSY UA73114
UP14/04/26 P F404 Ø
R780 PSY UA73115
UP14/04/26 P F404 Ø
R790 PSY UA73116
UP14/04/26 P F404 Ø
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"790","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"790","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
02 May 2014