A fix is available
APAR status
Closed as program error.
Error description
ESQA may become exhausted during NIP processing with alternate subchannel set devices offline. Analysis of ESQA storage shows SLFP control blocks containing SSCBs were the highest consumers of storage. There will be multiple SSCBs for the same control unit, with these control units containing 3390D alternate subchannel set devices.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: D/T3990 D/T2107 D/T2105 users that configure * * PPRC Secondary, FlashCopy Target, and FBA * * volumes in an Alternate Subchannel Set. * **************************************************************** * PROBLEM DESCRIPTION: DASD UIM did not indicate that 3390D * * and 3390S volumes should remain * * offline. This caused IOS to allocate a * * Subsystem Control Block (SSCB) each * * time it encountered one of these * * devices. Eventually, ESQA storage was * * exhausted. * **************************************************************** * RECOMMENDATION: * **************************************************************** This APAR will indicate that base volumes configured to an Alternate Subchannel Set, including PPRC Secondary volumes and FlashCopy Target volumes and FBA volumes, should remain offline when the operating system is IPLed.
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
OA43171
Reported component name
DEVICE SUPPORT
Reported component ID
5695DF111
Reported release
D10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2013-08-23
Closed date
2013-09-18
Last modified date
2013-11-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA70787 UA70788 UA70789
Modules/Macros
CBDUS002
Fix information
Fixed component name
DEVICE SUPPORT
Fixed component ID
5695DF111
Applicable component levels
RC10 PSY UA70787
UP13/09/27 P F309
RD10 PSY UA70788
UP13/10/01 P F309
R210 PSY UA70789
UP13/09/27 P F309
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"D10"}]
Document Information
Modified date:
09 January 2021