OA41776: D ETR DISPLAYS STP SYNCHRONIZATION AFTER SWITCH TO LOCAL TIMING IEA380I NOT ISSUED AFTER SWITCH TO STP TIMING

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When a server loses STP synchronization z/OS systems running
    in a multi-system sysplex issue IEA394A and spin waiting for a
    reply. However, some systems will switch to local timing and
    continue running. These systems are:
    1. GDPS controlling system. New function via APARs OA28323 and
       OA26085 allows the GDPS controlling system to continue
       running in local timing mode for up to 80 minutes
    2. Monoplex systems - systems with PLEXCFG specified as XCFLOCAL
       or MONOPLEX in IEASYSxx
    
    The systems listed above can also switch to local timing even if
    the server does not lose STP synchronization but an STP sync
    check occurs where the offset is greater than the TIMEDELTA
    specified in CLOCKxx.
    When one of the systems listed above switches to local timing
    (either due to the server losing STP synchronization or
    TIMEDELTA being exceeded during STP sync check processing),
    D ETR wrongly displays STP synchronization.
    
    In the reported problem, a MONOPLEX system switched to local
    timing as TIMEDELTA was exceeded for an STP sync check. The
    syslog showed:
    
    After the server lost STP synchronization
    16:29:17.59  D ETR
    16:29:17.59  IEA386I 16.29.17 TIMING STATUS 925
                 SYNCHRONIZATION MODE = STP
                   THIS SERVER IS A STRATUM 2
                   CTN ID = CGBNET
                   THE STRATUM 1 NODE ID = 002818.M10.IBM.84.xxxxxx
                   THIS IS THE BACKUP TIME SERVER
                   NUMBER OF USABLE TIMING LINKS = 12
                   THIS SERVER HAS ONLY A SINGLE SOURCE OF TIMING
                   SIGNALS
                   THIS STP NETWORK HAS NO SERVER TO ACT AS ARBITER
    16:32:16.37  IEA389I THIS STP NETWORK HAS NO SERVER TO ACT AS
                 BACKUP
    16:32:18.44  IXC438I COORDINATED TIMING INFORMATION HAS BEEN
                         UPDATED FOR SYSTEM: SYSA
                         PREVIOUS CTNID: STPCTN
                         CURRENT TIMING: LOCAL
    16:35:32.78  D ETR
    16:35:32.78  IEA282I 16.35.32 TIMING STATUS 933
                 SYNCHRONIZATION MODE = LOCAL
                 THE ETR FACILITY IS NOT INSTALLED.
    
    
    After the server regained STP synchronization
    16:36:57.36 *IEA265I UNABLE TO SYNC TOD CLOCKS TO STP.
                 CPC CONTINUES IN LOCAL MODE.
    16:37:15.48  D ETR
    16:37:15.49  IEA386I 16.37.15 TIMING STATUS 939
                 SYNCHRONIZATION MODE = STP   <*** should be LOCAL
                   THIS SERVER IS A STRATUM 2
                   CTN ID = STPCTN
                   THE STRATUM 1 NODE ID = 002818.M10.IBM.84.xxxxxx
                   THIS IS THE BACKUP TIME SERVER
                   NUMBER OF USABLE TIMING LINKS = 12
                   THIS SERVER HAS ONLY A SINGLE SOURCE OF TIMING
                   SIGNALS
                   THIS STP NETWORK HAS NO SERVER TO ACT AS ARBITER
    
    For a GDPS controlling system that switches to local timing
    after the server loses STP synchronization, the syslog would
    show:
    
    09:43:08.06 *IEA381I THE STP FACILITY IS NOT USABLE.
                 SYSTEM CONTINUES IN LOCAL TIMING MODE.
    09:43:10.15  IXC438I COORDINATED TIMING INFORMATION HAS BEEN
                         UPDATED FOR SYSTEM: AAIS
                         PREVIOUS CTNID: ISCTEST
                         CURRENT TIMING: LOCAL
    09:43:10.15 *IXC410E SYSTEM AAIS LOST SYNCHRONIZATION WITH THE
                 TIMING NETWORK.
                 LOCAL TIMING MODE WILL BE ALLOWED FOR 80 MINUTES.
    
    09:44:11.28  D ETR
    09:44:11.28  IEA386I 09.44.11 TIMING STATUS 778
                 SYNCHRONIZATION MODE = STP    <*** should be LOCAL
                   THIS SERVER IS A STRATUM 0
                   CTN ID =
                   NUMBER OF USABLE TIMING LINKS =  0
                   THIS SERVER HAS ONLY A SINGLE SOURCE OF TIMING
    
    In addition, for the systems listed above that switch to local
    timing when STP synchronization is lost, after a switch back to
    STP synchronization, message
      IEA380I THIS SYSTEM IS NOW OPERATING IN STP TIMING MODE.
    is not issued.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users at z/OS HBB7770 and above running      *
    *                 in STP timing mode.                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: This apar addresses 2 problems:         *
    *                      1. DISPLAY ETR command response         *
    *                         incorrectly shows STP timing mode    *
    *                         when the timing mode switched from   *
    *                         STP to Local timing mode.            *
    *                      2. When in Local timing mode and then   *
    *                         STP synchronization is restored,     *
    *                         so that the system has switched      *
    *                         back to STP timing mode, message     *
    *                         IEA380I is not issued to inform      *
    *                         the user that the system is in       *
    *                         STP timing mode.                     *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Both issues occur in the Timing Alert External SLIH,
    IEATEEIH, during a timing status change event.
    
    1.  The field to indicate STP timing mode is incorrectly set
        during an unsynchronized timing state change.  A timing
        mode change can not be set during an unsynchronized
        timing state change.
    2.  The field used to check to issue MSGIEA380I is improperly
        set causing the check to always fail.
    
    Additional keywords:  STP/K
    

Problem conclusion

  • Both problems can be solved by one solution.  In IEATEEIH,
    fix the check for a synchronized timing state change to
    correctly set the STP timing mode indicator and the
    issuance of MSGIEA380I.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA41776

  • Reported component name

    TIMER SUPERVISO

  • Reported component ID

    5752SC1CV

  • Reported release

    780

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-03-22

  • Closed date

    2013-04-23

  • Last modified date

    2013-10-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA68905 UA68906 UA68907

Modules/Macros

  • IEATEEIH
    

Fix information

  • Fixed component name

    TIMER SUPERVISO

  • Fixed component ID

    5752SC1CV

Applicable component levels

  • R770 PSY UA68905

       UP13/05/08 P F305

  • R780 PSY UA68906

       UP13/05/08 P F305

  • R790 PSY UA68907

       UP13/05/08 P F305

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"780","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"780","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
07 October 2013