A fix is available
APAR status
Closed as program error.
Error description
EAVs take an extremely long time to come to duplex when initiallay XADDed or after a suspension
Local fix
Add EAVs before other volumes
Problem summary
**************************************************************** * USERS AFFECTED: Users of Extended Remote Copy (XRC) * * mirroring Extended Address Volumes (EAVs) * **************************************************************** * PROBLEM DESCRIPTION: Extended Address Volumes (EAVs) * * take an extremely long time to come to * * duplex when initially XADDed * * or after a suspension. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
XRC is changed to allow a new volume selection mode, SIZE, when performing initial volume synchronization or resynchronization. SIZE instructs XRC to select volumes based on their total number of cylinders. This allows EAVs to start synchronization sooner and overlap processing with smaller volumes. The following updates will be reflected in a future revision of the z/OS DFSMS Advanced Copy Services manual (SC35-0428): In the section ANTXIN00 parmlib parameters, change the table entry for SelectionAlgorithm to include SIZE in the Ranges/ Values cell. Add the following at the end of the paragraph describing SelectionAlgorithm: Specification of SIZE directs the system data mover to select volumes based on total number of cylinders, choosing the largest first, from the set of volumes that have been successfully XADDed up to that point. The existing parameters MaxNumberInitializations, InitializationsPerPrimary and InitializationsPerSecondary will be honored; in addition, to avoid overloading storage control sessions, selection by SIZE will prefer the volume with largest number of cylinders on the controller with the least residual load. If there are multiple volumes with the same number of cylinders on controllers with the same residual load, the volume that was initially XADDed first will be the next to be processed. The following updates will be reflected in a future revision of z/OS MVS System Messages, Volume 1(ABA-AOM)(SA22-7631): Add the following to the description of 'priority' in the ANTQ8262I message: SIZE-Add volumes based on their total number of cylinders, from largest to smallest KEYWORDS: D/T2105 D/T2107 EAV/K XRC/K
Temporary fix
Comments
APAR Information
APAR number
OA40698
Reported component name
SYSTEM DATA MOV
Reported component ID
5695DF117
Reported release
C10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-10-26
Closed date
2013-10-01
Last modified date
2014-03-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA70924 UA70925 UA70926 OA43540
Modules/Macros
ANTCVXT2 ANTRQTA ANTS4011 ANTS4064 ANTS4068 ANTS4101 ANTS4926 ANTXC00I ANTXISET ANTXTUN1 ANTXTUN2 ANTXTUN3
| SC350428XX | SA227631XX |
Fix information
Fixed component name
SYSTEM DATA MOV
Fixed component ID
5695DF117
Applicable component levels
RC10 PSY UA70924
UP13/10/15 P F310
RD10 PSY UA70925
UP13/10/15 P F310
R210 PSY UA70926
UP13/10/15 P F310
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.