OA39747: FSS PRINTER STATUS SHOWS AS INACTIVE IN SDSF, $DPRTX SHOWS ACTIVE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • SDSF TSO users on the PR (printer) panel will see incorrect
    FSS printer status. Similar to OA38226. A $DPRTx shows printer
    as ACTIVE. This may occur after printer setup message $HASP190
    is issued. At this point the SDSF printer status as well as the
    $DPRTx display will show HALTED. After $SPRTx is issued SDSF
    will show INACTIVE while $DPRTx shows ACTIVE.
    
    The CDCT copy of the device status used by SSI83 for the SDSF
    display is updated incorrectly.
    
    Verification steps:
    See problem description. If FSS printer and PRESELCT=YES set
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of HJE7770 and HJE7780.            *
    ****************************************************************
    * PROBLEM DESCRIPTION: SDSF PR panel falsely shows a           *
    *                      printer as inactive.                    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    JES2 SSI 83 data returned to applications such as SDSF
    is flawed.  The management of device activity falsely
    removes data for a job active on a printer.
    

Problem conclusion

  • TYPE/RESTART(WARM) IPL/REQUIRED(YES) CLPA(YES)
    
    CLPA is needed only if HASCxxxx modules currently reside in
    the pageable link pack area (PLPA).
    
    ENF processing is updated to manage printer status
    properly.
    
    In order to completely fix this problem, APARs OA39305
    and OA38630 must also be applied.
    
    **********************************************************
    *                                                        *
    *  You may continue to experience this problem until all *
    *  members of the MAS have this fix applied.             *
    *                                                        *
    **********************************************************
    
    APAR OA39747 prereq's (and sup's) for FMID HJE7770:
    Pre's: FA38630 FA39305 FA37230
    
    APAR OA39747 prereq's (and sup's) for FMID HJE7780:
    Pre's: GA38630 GA39305 GA37230
    

Temporary fix

  • *** * TEMPORARY FIX MAY BE OBTAINED FROM DLL OR INFO/ACCESS ****
    ******************* OA39747  DECK AVAILABLE ********************
    

Comments

APAR Information

  • APAR number

    OA39747

  • Reported component name

    JES2

  • Reported component ID

    5752SC1BH

  • Reported release

    770

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / Pervasive / Xsystem

  • Submitted date

    2012-06-07

  • Closed date

    2012-11-29

  • Last modified date

    2013-01-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA67331 UA67332

Modules/Macros

  • HASCENF  HASCSRDS
    

Fix information

  • Fixed component name

    JES2

  • Fixed component ID

    5752SC1BH

Applicable component levels

  • R770 PSY UA67331

       UP12/12/12 P F212

  • R780 PSY UA67332

       UP12/12/12 P F212

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"770","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"770","Edition":"","Line of Business":{"code":"","label":""}}]