A fix is available
APAR status
Closed as program error.
Error description
When a 0A30(SVC 30)is executed the flags indicate a UCB is being passed and the UCB Address is all zero's. This causes CICS to abend with an abendS430. CICHD000 PLX is not setting up the DEQ (SVC30) correctly.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All. * **************************************************************** * PROBLEM DESCRIPTION: Rexx EXPORT command may abend AKEB, * * CICS terminates. * **************************************************************** * RECOMMENDATION: * **************************************************************** In the reported problem, a REXX EXPORT command was issued by The REXX Runtime facility running on the CICS Transaction Server for z/OS. . The EXPORT command has a 'target' parameter which is the name of an allocated MVS dataset. However, the dataset did not exist. As a consequence, the UCB ( Unit Control Block ) pointer at offset x'C' in the parameter list for the SVC 30 was null. This caused the SVC to fail. An abendAKEB was issued and CICS terminated.
Problem conclusion
Module CICHD000 has been modified to bypass the aforementioned SVC 30 call if the Unit Control Block pointer is null.
Temporary fix
FIX AVAILABLE BY PTF ONLY
Comments
APAR Information
APAR number
OA36609
Reported component name
REXX/CICS COMM
Reported component ID
565511200
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-05-27
Closed date
2012-01-11
Last modified date
2012-02-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA63770
Modules/Macros
CICHD000
Fix information
Fixed component name
REXX/CICS COMM
Fixed component ID
565511200
Applicable component levels
R110 PSY UA63770
UP12/01/13 P F201
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
02 February 2012