IBM Support

OA34623: DCOLLECT ERRORS WHEN PROCESSING MULTIPLE VOLUME HFS DATA SETS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • DCOLLECT issues the following error messages when processing the
    second and subsequent volumes of a multiple volume HFS data set:
    
    IDC11808I ERRORS WERE DETECTED FOR
              SYS1.OMVS.DB2810.HFS.DB2DAS ON
    IDC11808I SYS309 - ERROR BYTE WAS X'20'
    IDC21814I FAILURE DURING DASD CALCULATION SERVICE PROCESSING FOR
    IDC21814I SYS1.OMVS.DB2810.HFS.DB2DDA
    IDC21814I RETURN CODE WAS 4
    
    Output from LISTC command indicates that the data set being
    processed is a multiple volume HFS.
    
    Additionally DASDCALC services records the following EREP
    symptom record:
    =============================
    PIDS/5695DF104 RIDS/IGWFAMS  RIDS/IGBDCS#L   PRCS/00000008
    PRCS/282801FF
    =============================
    
    The FAMS reason code 282801FF is being issued from the FAMS
    module IGWAMAM8 and equates RSC_OP0_DSN_NOT_FOUND. (data set not
    found)
    
    DCOLLECT call FAMS with a GET_ATTRIBUTE request to obtain the
    pages used for the data set on the volume. The DCOLLECT FAMS
    call pass a single volume, however; FAMS should recognize that
    this is a mutliple volume data set and process accordingly.
    
    ADDITIONAL KEYWORD: PDSE/K
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DFSMS DCOLLECT with multivolume HFS *
    *                 data sets.                                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: DCOLLECT ERRORS WHEN PROCESSING         *
    *                      MULTIPLE VOLUME HFS DATA SETS           *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    DCOLLECT issues the following error messages when processing the
    second and subsequent volumes of a multiple volume HFS data set:
    
    IDC11808I ERRORS WERE DETECTED FOR
              SYS1.OMVS.DB2810.HFS.DB2DAS ON
    IDC11808I SYS309 - ERROR BYTE WAS X'20'
    IDC21814I FAILURE DURING DASD CALCULATION SERVICE PROCESSING FOR
    IDC21814I SYS1.OMVS.DB2810.HFS.DB2DDA
    IDC21814I RETURN CODE WAS 4
    
    Output from LISTC command indicates that the data set being
    processed is a multiple volume HFS.
    

Problem conclusion

  • FAMS HFS processing has been changed to test for multivolume
    data sets before calling USS for attributes.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA34623

  • Reported component name

    EXTENDED DATA S

  • Reported component ID

    5695DF115

  • Reported release

    B10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / Pervasive

  • Submitted date

    2010-10-14

  • Closed date

    2011-01-13

  • Last modified date

    2014-03-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA58685 UA58686 UA58687

Modules/Macros

  • IGWAMAM8
    

Fix information

  • Fixed component name

    EXTENDED DATA S

  • Fixed component ID

    5695DF115

Applicable component levels

  • RA10 PSY UA58685

       UP11/03/01 P F102

  • RB10 PSY UA58686

       UP11/03/01 P F102

  • RC10 PSY UA58687

       UP11/03/01 P F102

Fix is available