IBM Support

OA33230: EXECUTION OF AN SYSSMS CTRACE TO AN EXTERNAL WRITER IS FAILING *FINREVERSAL*

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The execution of an SYSSMS CTRACE with output to an external
    writer is failing with a loop in IGWFTREN code at the z/OS 1.10
    level. The loop occurs between offset 000F3E and 00F9C for a
    the module.
    
    ===========================================
    TRACE CT,ON,COMP=SYSSMS,PARM=CTISMSJC
    
    IEE252I MEMBER CTISMSJC FOUND IN SYS1.PARMLIB
    ITT038I ALL OF THE TRANSACTIONS REQUESTED VIA THE TRACE CT
            COMMAND WERE SUCCESSFULLY EXECUTED.
    
    IEE843I TRACE DISPLAY SYSTEM STATUS INFORMATION
            ST=(ON,0001M,00002M) AS=ON  BR=OFF EX=ON MO=OFF
            MT=(ON,024K)
            COMPONENT     MODE BUFFER HEAD SUBS
            -------------------------------------------------------
            SYSSMS        ON   0072K
            ASIDS      *NONE*
            JOBNAMES   IMSPE1MF,IMSPE1MI,IMSPE1MJ,IMSPE1M7
            OPTIONS    ENTRY,EXIT,COMP=(CDM,BMF)
            WRITER     CTWTR
    IEE178I AUTOMATIC RECOVERY IS IN PROGRESS
            NO OPERATOR ACTION IS REQUIRED.
            PROCESSOR (00) DETECTED AN EXCESSIVE DISABLED SPIN LOOP,
            WAITING FOR LOCK RELEASE FROM PROCESSOR (01).
            AUTOMATIC RECOVERY ACTION IS SPIN
    ======================================
    ADDITIONAL KEYWORD: PDSE/K
    

Local fix

  • Change CTRACE processing to write to an internal trace buffer:
    
    TRACEOPTS
       ON
       JOBNAME(xxxxxxxx)
       OPTIONS('ENTRY','EXIT','COMP=(CDM,BMF)')
       BUFSIZE(64M)
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: USERS RUNNING CTRACE FOR PDSES.              *
    ****************************************************************
    * PROBLEM DESCRIPTION: EXECUTION OF AN SYSSMS CTRACE WITH      *
    *                      OUTPUT TO AN EXTERNAL WRITER FAILS WITH *
    *                      A LOOP IN IGWFTREN.  THIS HAS NOT BEEN  *
    *                      SEEN WHEN TRACING THE SMSPDSE(1)        *
    *                      ADDRESS SPACE BUT HAS OCCURRED WHEN     *
    *                      TRACING AN APPLICATION ADDRESS SPACE.   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    EXECUTION OF AN SYSSMS CTRACE WITH OUTPUT TO AN EXTERNAL WRITER
    FAILS WITH A LOOP IN IGWFTREN.
    

Problem conclusion

  • CHANGED CODE TO NOT TRY TO EXPAND THE TRACE TABLE IF THE CALLER
    OF TRACE WAS DISABLED.  THE TRACE WILL BE SKIPPED.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA33230

  • Reported component name

    EXTENDED DATA S

  • Reported component ID

    5695DF115

  • Reported release

    A10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-05-27

  • Closed date

    2010-06-25

  • Last modified date

    2014-03-28

  • APAR is sysrouted FROM one or more of the following:

    OA30844

  • APAR is sysrouted TO one or more of the following:

    UA55237 UA55238 UA55239 UA55240

Modules/Macros

  • IGWFTREN
    

Fix information

  • Fixed component name

    EXTENDED DATA S

  • Fixed component ID

    5695DF115

Applicable component levels

  • RA10 PSY UA55237

       UP10/08/18 P F008

  • RB10 PSY UA55238

       UP10/08/18 P F008

  • RC10 PSY UA55239

       UP10/08/18 P F008

  • R190 PSY UA55240

       UP10/08/18 P F008

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
28 March 2014