IBM Support

OA31751: SYSTEM COMPLETION CODE=0C4 REASON CODE=00000011

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • the problem is definitely related to VIO datasets. An address we
    have passed to us is not addressable by the code at that point.
    Sometimes the address is a valid address within the OMEGAMON
    address space, so the ABEND does not occur.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All OMEGAMON II for CICS users.              *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND S0C4 in KOCDX0CA using interval   *
    *                      recording and VIO datasets in DFHRPL    *
    *                      concatenation in CICS.                  *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF.                               *
    ****************************************************************
    The UCB for VIO datasets is not in common storage and so is
    not addressable from the collector address space.
    

Problem conclusion

  • The OMEGAMON code was changed to handle VIO UCBs correctly.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA31751

  • Reported component name

    OMEGA II FOR CI

  • Reported component ID

    5608A0100

  • Reported release

    560

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-01-23

  • Closed date

    2010-03-16

  • Last modified date

    2010-05-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA53212 OA32641

Modules/Macros

  • KOCCEP0A KOCFILAA
    

Fix information

  • Fixed component name

    OMEGA II FOR CI

  • Fixed component ID

    5608A0100

Applicable component levels

  • R560 PSY UA53212

       UP10/04/10 P F004

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSNU33","label":"Tivoli OMEGAMON II for CICS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"560","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: