OA21981: MPMU ENVIRONMENT , USP STORAGE LEAK , INITUSP , abend878 abend80A

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • In a MPMU address space, a process dubbing and
    undubbing will get a USP created for it each time through
    DUB.  The previous USP is not freed and the storage
    is lost.
    In the path for a MPMU (multiproc/multiuser) address space,
    BPXPRIN1 does not check the ACEEIUSP bit to see if there is
    already a USP (user security package) connected to this ACEE.
    This causes a storage leak in ELSQA, leading to multiple
    abend80A's and abend878's.
    .
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of Tivoli NetView for z/OS who     *
    *                 make use of UNIX System Services, including  *
    *                 System Automation/390 (SA/390).              *
    ****************************************************************
    * PROBLEM DESCRIPTION: A new USS dub setting is needed for     *
    *                      NetView to allow the fix for USS APAR   *
    *                      OA20171 to be effective.                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The fix provided by USS APAR OA20171 requires that the job step
    task of the address space specifies a new option, DUBUNIQUEACEE,
    on the Set Dub Defaults (BPX1SDD) invocation. Doing so will
    allow the problem described by OA20171 to be resolved.
    

Problem conclusion

  • Module DSIDUBIT is being changed to attempt to invoke the
    BPX1SDD callable service with varying combinations of options,
    starting with all the ones required by NetView. If the request
    fails, another attempt will be made using less
    recently-available options. For each attempt that fails,
    msgBNH284E will be issued stating that the specific function is
    not available. When an invocation of BPX1SDD works, msgCNM910I
    will be issued stating which options were successful. The
    options that are attempted follow, in the order they will be
    attempted:
      PROCESSDEFER+JOBPERM+NOJSTUNDUB+UNIQUEACEE
      PROCESSDEFER+JOBPERM+NOJSTUNDUB
      PROCESSDEFER
      PROCESS
    Also, because messages BNH284E and CNM910I are being used in
    this new way, the descriptions of these messages are being
    changed. To do so, the Tivoli NetView for z/OS V5R2 Messages and
    Codes Volume 1 (AAU-DSI) (SC31-6965-00) and the Tivoli NetView
    for z/OS V5R3 Messages and Codes Volume 1 (AAU-DSI)
    (SC31-6965-01) should be changed as follows:
     The description of message BNH284E should be changed as
     follows:
      The description of the 'function' message variable should be
      changed to read as follows:
       function The function that your current installation does not
                support
      The Operator Response should be changed to read as follows:
       Operator Response: If appropriate, verify that the command
       was entered correctly, then correct and reenter the command
       request.
    
       If the command is 'BPX1SDD', then the UNIX System Services
       Set Dub Defaults request issued by the NetView program during
       its initialization has failed when attempting to specify the
       options indicated by 'function'.
    
       If support for the function should be available, contact your
       system programmer and indicate that the specified function
       has not been installed.
     The description of message CNM910I should be changed as
     follows:
      New Operator Response and System Programmer Response sections
      should be added to read as follows:
       Operator Response: If 'command' begins with 'BPX1SDD', then
       the UNIX System Services Set Dub Defaults request has
       succeeded with the indicated options. One or more instances
       of message BNH284E may have been issued. If no previous
       BNH284E had been issued, all the latest UNIX System Services
       dub defaults functions are installed.
    
       System Programmer Response: None.
    The online help for messages BNH284E and CNM910I are being
    changed as described above.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA21981

  • Reported component name

    NETVIEW FOR Z/O

  • Reported component ID

    5697ENV00

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function

  • Submitted date

    2007-07-25

  • Closed date

    2008-03-25

  • Last modified date

    2008-06-02

  • APAR is sysrouted FROM one or more of the following:

    OA20171

  • APAR is sysrouted TO one or more of the following:

    UA40201 UA40202 UA40203 UA40204 UA40205 UA40206

Modules/Macros

  • BNH28    CNM91    DSIDUBIT DSIOEMAC
    

Publications Referenced
SC31696501SC31696500   

Fix information

  • Fixed component name

    NETVIEW FOR Z/O

  • Fixed component ID

    5697ENV00

Applicable component levels

  • R520 PSY UA40201

       UP08/05/17 P F805

  • R521 PSY UA40203

       UP08/05/17 P F805

  • R522 PSY UA40204

       UP08/05/17 P F805

  • R53B PSY UA40202

       UP08/05/16 P F805

  • R53E PSY UA40205

       UP08/05/16 P F805

  • R53J PSY UA40206

       UP08/05/16 P F805

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJDU","label":"IBM Z NetView"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
02 June 2008