IBM Support

MA49559 - LIC-COMM-OTHER SOCKETS RECEIVE DATA FAILS AFTER REMOTE CLOSE
END OF ABSTRACT

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

APAR (Authorized Program Analysis Report)

Abstract

LIC-COMM-OTHER SOCKETS RECEIVE DATA FAILS AFTER REMOTE CLOSE
END OF ABSTRACT

Error Description

Remote side of a connection closes and the local socket issues  
a send that fails with errno value of EPIPE. Receives fail      
with errno value of ECONNRESET, even if there is valid data    
queued.                                                        

Problem Summary

After the remote side of a connection closes and the local      
socket issues a send that fails with errno value of EPIPE,      
receives fail with errno value of ECONNRESET even if there is  
valid data queued.                                              

Problem Conclusion

The receive code path was updated so that any valid data queued
on the socket is returned after the remote side is reset. After
all data is received from the socket, the next receive fails    
with errno value of ECONNRESET. Additional receives after that  
point get a return code of 0 indicating end of file.            

Temporary Fix

Comments

The receive code path was updated so that any valid data queued
on the socket is returned after the remote side is reset. After
all data is received from the socket, the next receive fails    
with errno value of ECONNRESET. Additional receives after that  
point get a return code of 0 indicating end of file.            

Circumvention


PTFs Available

R720 MF69702  1000

R730 MF69652  1000

R740 MF69730  1000

R750 MF69703  1000

Affected Modules


         
         

Affected Publications

Summary Information

Status............................  CLOSED PER
HIPER.............................  No
Component.........................  9400DG300
Failing Module....................  RCHMGR
Reported Release..................  R750
Duplicate Of......................  




IBM i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019, 2020, 2021, 2022 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information