Abstract

LIC-DISK-STG-SRCB6005121-INCORROUT SYSTEM MSD B6005121 0D200061
0002000A 00100011 WHILE RUNNING STRASPBAL

Error Description

System generated a MSD shortly after customer ran STRASPBAL    
SRC word 1 . . . . . . . . . . : B6005121                      
SRC word 2 . . . . . . . . . . : 0D200061                      
SRC word 3 . . . . . . . . . . : 0002000A                      
SRC word 4 . . . . . . . . . . : 00100011                      
SRC word 5 . . . . . . . . . . : 00000000                      
SRC word 6 . . . . . . . . . . : 00000000                      
SRC word 7 . . . . . . . . . . : 00000000                      
SRC word 8 . . . . . . . . . . : 00000000                      
SRC word 9 . . . . . . . . . . : 00000000                      
Type/Model/Feature . . . . . . : 8286 041A EPXK                
System name . . . . . . . . . : S2157E2V                        
LIC level . . . . . . . . . . : V7R2M0                          
Main storage size (megabytes) : 61696                          
MSD size (megabytes) . . . . . : 61696                          
Residue only . . . . . . . . . : No                            
IPL side . . . . . . . . . . . : B                              

Problem Summary

When running STRASPBAL TYPE(*MP) the system terminated with the
following SRC:                                                  
                                                               
SRC word 1 . . . . . . . . . . : B6005121                      
SRC word 2 . . . . . . . . . . : 0D200061                      
SRC word 3 . . . . . . . . . . : 0002000A                      
SRC word 4 . . . . . . . . . . : 00100011                      

Problem Conclusion

The problem is fixed.                                          

Temporary Fix

Comments

Circumvention


PTFs Available

R710 MF59232 PTF Cover Letter   5142
R720 MF59231 PTF Cover Letter   5135

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... No
Component.................................. 9400DG300
Failing Module.......................... RCHMGR
Reported Release................... R720
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.2.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R1M0;V7R2M0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
30 May 2015