IBM Support

LO81247: "FIELD IS TOO LARGE (32K) OR VIEW'S COLUMN & SELECTION FORMULAS ARE TOO LARGE" OCCURS INFLUENCED BY $MIMETRACK.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as fixed if next.

Error description

  • XPage which has rich text control creates a record in $MIMETrack
    when saving document.   $MIMTrack item has a lot of data after
    the document is updated repeatedly and $MIMETrack item is
    summary field.  The document As a result, the following errors
    occurs.
    "Field is too large (32K) or View's column & selection formulas
    are too large"
    
    If MIMETrack  is full (32K), a current data does not enter.
    L2 thinks that size limitation feature is needed for $MIMETrack
    like a $Revisions.
    
    Steps to reproduce:
    1. Create a document which has the MIMETrack of a maximum size
    (32k).
    2. Opens the database via a web browser.
    3. Open one document from xpage view control to edit it.
    4. Put some string in the text field and body field.
    5. Push the save button.   The error occurs.
    If the error does not occur, repeat step 4 and 5.
    

Local fix

  • Deleting $MIMETrack item.
    

Problem summary

  • This APAR is closed as FIN. We have deferred the fix to a
     future release.
    

Problem conclusion

Temporary fix

Comments

  • This APAR is associated with SPR# YSAI9M3BQW.
    This APAR is closed as FIN. We have deferred the fix to a
     future release.
    

APAR Information

  • APAR number

    LO81247

  • Reported component name

    DOMINO SERVER

  • Reported component ID

    5724E6200

  • Reported release

    850

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-07-16

  • Closed date

    2018-04-07

  • Last modified date

    2018-04-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU055","label":"Cognitive Applications"},"Product":{"code":"SSKTMJ","label":"Lotus Domino"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
07 April 2018