IBM Support

LO64433: 'THIS FIELD IS NOT A VALID NUMBER' ERROR IN XPAGE USING WINDOWS FRENCH

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • You have an XPage with an Edit Box set to a number. On the
    afterPageLoad event, you set the Edit box value to 100000.
    Example:
    
    var total = 100000;
    getComponent("myEditBox").setValue(total);
    
    On US English Windows, after the page loads, the value looks
    like this 100,000.  And if you try to put the XPage in edit
    mode, everything works fine.  On a French Windows workstation
    however, the value after page load is like this 100 000 (space
    instead of the comma).  If you try to put the XPage in edit
    mode, you get 'This field is not a valid number' error.
    

Local fix

  • N/A
    

Problem summary

  • A programming error was found and will be corrected in a future
     release.
    

Problem conclusion

  • A programming error was found and will be corrected in a future
     release.
    

Temporary fix

Comments

  • This APAR is associated with SPR# OIHZ8MC3DP.
    A programming error was found and will be corrected in a future
     release.
    

APAR Information

  • APAR number

    LO64433

  • Reported component name

    NOTES CLIENT

  • Reported component ID

    5724E6255

  • Reported release

    852

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-10-04

  • Closed date

    2012-09-03

  • Last modified date

    2012-09-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    NOTES CLIENT

  • Fixed component ID

    5724E6255

Applicable component levels

  • R852 PSN

       UP

[{"Business Unit":{"code":"BU055","label":"Cognitive Applications"},"Product":{"code":"SSKTWP","label":"Lotus Notes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5.2","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
03 September 2012