IBM Support

LO47480: RICH TEXT CONTROLS NOT WORKING IN IE8 OVER SSL

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as user error.

Error description

  • You have an XPage with an Rich Text Control on your Domino 8.5.1
    server.  When
    you access the XPage over SSL in IE 8, you receive an error:
    Navigation to the
    webpage was canceled.  This is only reproducible on Domino 8.5.1
    using IE8 over
    SSL (HTTPS).
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

  • This APAR is associated with SPR# OIHZ7YYQH8.
    Per dev: The error was caused by an invalid ssl configuration
     on the server where the keyring file did not exist, that
     causes the browser to fail to connect to the server.      I
     cannot reproduce the issue on 852 with a valid and correct ssl
     keyring file and configuration.    Also the original screen
     shot is showing a certificate error (see second line of text
     under the title bar of ie 8), this also appears to be a ssl
     configuration problem with the server.      By default there
     is no keyring file and one must be created via the certificate
     authority. A self signed certificate is used for testing
     purposes.   The certificate error shown in the screen shot
     also points to a ssl config issue, in that the certificate is
     not signed correctly.  There are a series of steps to
     configure your server and create a signed certificate keyring
     file which can be found on the IBM website under the support
     section.
    

APAR Information

  • APAR number

    LO47480

  • Reported component name

    DOMINO SERVER

  • Reported component ID

    5724E6200

  • Reported release

    850

  • Status

    CLOSED USE

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-12-22

  • Closed date

    2010-03-29

  • Last modified date

    2010-03-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU055","label":"Cognitive Applications"},"Product":{"code":"SSKTMJ","label":"Lotus Domino"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
29 March 2010