IBM Support

LI76416: TABLEQUEUE MONITORS, ROWS RECEIVED AND SENT ON TABLEQUEUES ARE N OT CORRECT IN DPF WITH INTRA PARTITION PARALLELISM ENABLED.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Tablequeue monitors, eg.:
    .
    Rows received on tablequeues
    Rows sent on tablequeues
    .
    In a DPF environment with intra partition parallelism enabled
    , the above monitor elements are not properly calculated leading
    to misleading data.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users using DPF + SMP (intra parallel enabled) and           *
    * monitoring TQ activity.                                      *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See Error Description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to DB2 v95 fixpack 9 or higher                       *
    ****************************************************************
    

Problem conclusion

  • Problem fixed in DB2 Version 9.5 Fix Pack 9
    

Temporary fix

Comments

APAR Information

  • APAR number

    LI76416

  • Reported component name

    DB2 UDE ESE LIN

  • Reported component ID

    5765F4104

  • Reported release

    950

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-08-18

  • Closed date

    2012-04-04

  • Last modified date

    2012-04-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IC78204

Fix information

  • Fixed component name

    DB2 UDE ESE LIN

  • Fixed component ID

    5765F4104

Applicable component levels

  • R950 PSY

       UP

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSEPGG","label":"DB2 for Linux, UNIX and Windows"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"950","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]