Direct link to fix
APAR status
Closed as program error.
Error description
When you use an Integer data type for the binding, the Single Select component doesn't consider the binding variable value. The selected value from the binding variable is not shown in the Single Select component when the coach is loaded. PRODUCTS AFFECTED IBM Business Automation Workflow
Local fix
Use a String data type for the binding instead of an Integer data type or in the "On load" event of the Single Select specify the following where Single_Select1 is the Control ID. ${Single_Select1}.setSelectedItem(${Single_Select1}.getSelectedI tem());
Problem summary
No additional information is available.
Problem conclusion
A fix is available or will be available that ensures the selected value from the Integer binding variable is shown in the Select Single coach view when the coach is loaded.
Temporary fix
Comments
APAR Information
APAR number
JR62558
Reported component name
BUS AUTO WORKFL
Reported component ID
5737H4100
Reported release
J00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-07-16
Closed date
2020-07-27
Last modified date
2020-07-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BUS AUTO WORKFL
Fixed component ID
5737H4100
Applicable component levels
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS8JB4","label":"IBM Business Automation Workflow"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"19.0.0.1"}]
Document Information
Modified date:
14 December 2020