Direct links to fixes
APAR status
Closed as program error.
Error description
Connecting Integration Designer to Workflow Center in IBM Business Automation Workflow V19.0.0.3 fails. You might see following exception in the Integration Designer log files: !ENTRY com.ibm.wbit.lombardi.core 4 0 2020-05-14 09:56:45.915 !MESSAGE Could not connect to endpoint service !STACK 0 com.ibm.bpm.common.rest.RESTBadRCException: . t3027-dev001-sng at com.ibm.bpm.common.rest.impl.RepositorySession.executeHttpMethod (RepositorySession.java:343) at com.ibm.bpm.common.rest.impl.RepositorySession.executeGETHelper( RepositorySession.java:170) at com.ibm.bpm.common.rest.impl.RepositorySession.executeGETMethod( RepositorySession.java:155) at com.ibm.wbit.lombardi.core.utils.BPMRepoRESTUtils.getBPMUrlFromS erver(BPMRepoRESTUtils.java:1912) at com.ibm.wbit.lombardi.core.utils.BPMRepoRESTUtils.getBPMUrl(BPMR epoRESTUtils.java:1827) at com.ibm.wbit.ui.internal.processcenterview.PlugableLoginHandler. bootstrap(PlugableLoginHandler.java:287) at com.ibm.wbit.ui.internal.processcenterview.PlugableLoginHandler. setupEnvironment(PlugableLoginHandler.java:259) at com.ibm.wbit.ui.internal.processcenterview.ConnectionTester$1.ru n(ConnectionTester.java:202) at com.ibm.wbit.ui.internal.processcenterview.ConnectionTester.test (ConnectionTester.java:220) at com.ibm.wbit.ui.internal.processcenterview.ConnectionTester.test (ConnectionTester.java:185) at com.ibm.wbit.ui.internal.processcenterview.ConnectionTester.test (ConnectionTester.java:179) at com.ibm.wbit.ui.internal.processcenterview.ProcessCenterView.tes tConnection(ProcessCenterView.java:674) at com.ibm.wbit.ui.internal.processcenterview.ProcessCenterView.loa d(ProcessCenterView.java:550) at com.ibm.wbit.ui.internal.processcenterview.ProcessCenterView.acc ess$2(ProcessCenterView.java:542) at com.ibm.wbit.ui.internal.processcenterview.ProcessCenterView$7.f unction(ProcessCenterView.java:609)
Local fix
Problem summary
As part of the changes for interim fix JR61528 for Business Automation Workflow V19.0.0.3, requests for internal endpoints no longer use the EXTERNAL_CLIENT URL. Instead, these requests now use the INTERNAL_CLIENT URL. However, Integration Designer depended on the previous URL and couldn't access the INTERNAL_CLIENT URL in some cases. As a result, connecting to Workflow Center fails. PRODUCT AFFECTED Integration Designer
Problem conclusion
A fix is available or will be available that lets Integration Designer request the client endpoint that it needs from the server.
Temporary fix
Comments
APAR Information
APAR number
JR62465
Reported component name
BUS AUTO WORKFL
Reported component ID
5737H4100
Reported release
K00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-06-22
Closed date
2020-08-06
Last modified date
2020-08-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BUS AUTO WORKFL
Fixed component ID
5737H4100
Applicable component levels
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS8JB4","label":"IBM Business Automation Workflow"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"20.0.0.1"}]
Document Information
Modified date:
14 December 2020