IBM Support

JR61878: DB2 CONNECTOR WITH PARAMETRIZED ALTERNATE CONDUCTOR SETTINGS FAILS TO QUERY DATABASE CONFIGURATION

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • DB2 Connector with parametrized Alternate conductor settings
    fails to query database configuration when main and alternate
    Database/Location properties are configured with different
    names and Alternate conductor settings is disabled by parameter
    value.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    DB2 Connector users using parameters to control Alternate
    conductor settings
    ****************************************************************
    PROBLEM DESCRIPTION:
    The use of a parameter to control Alternate conductor settings
    implies the need to set the alternate Database/Location property
    value. When preparing input data for db2CfgGet to query the
    database configuration the DB2 Connector uses the alternate
    database name without checking whether Alternate conductor
    settings is enabled.
    As a consequence incorrect database name may be used in the
    db2CfgGet call, if the main and alternate Database/Location
    names differ, resulting in job failure with following error
    message:
    An error occurred while preparing the table partitioning
    information.
    The method db2CfgGet returned reason code 0, SQLCODE -1,013.
    The SQLCODE may vary between -1,013, if the alternate database
    name cannot be found in the DB2 client's database catalog, and
    -30,082 otherwise.
    ****************************************************************
    RECOMMENDATION
    apply patch for JR61878
    ****************************************************************
    

Problem conclusion

  • DB2 Connector routine checking the database configuration has
    been updated to pick the database name depending on the state
    Alternate conductor settings state.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR61878

  • Reported component name

    WIS DATASTAGE

  • Reported component ID

    5724Q36DS

  • Reported release

    B70

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-01-10

  • Closed date

    2020-01-30

  • Last modified date

    2020-01-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WIS DATASTAGE

  • Fixed component ID

    5724Q36DS

Applicable component levels

  • RB71 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"InfoSphere DataStage"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"11.7","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
15 October 2021