Error description
DB2 Connector with parametrized Alternate conductor settings fails to query database configuration when main and alternate Database/Location properties are configured with different names and Alternate conductor settings is disabled by parameter value.
Local fix
Problem summary
**************************************************************** USERS AFFECTED: DB2 Connector users using parameters to control Alternate conductor settings **************************************************************** PROBLEM DESCRIPTION: The use of a parameter to control Alternate conductor settings implies the need to set the alternate Database/Location property value. When preparing input data for db2CfgGet to query the database configuration the DB2 Connector uses the alternate database name without checking whether Alternate conductor settings is enabled. As a consequence incorrect database name may be used in the db2CfgGet call, if the main and alternate Database/Location names differ, resulting in job failure with following error message: An error occurred while preparing the table partitioning information. The method db2CfgGet returned reason code 0, SQLCODE -1,013. The SQLCODE may vary between -1,013, if the alternate database name cannot be found in the DB2 client's database catalog, and -30,082 otherwise. **************************************************************** RECOMMENDATION apply patch for JR61878 ****************************************************************
Problem conclusion
DB2 Connector routine checking the database configuration has been updated to pick the database name depending on the state Alternate conductor settings state.
Temporary fix
Comments
APAR Information
APAR number
JR61878
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
B70
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-01-10
Closed date
2020-01-30
Last modified date
2020-01-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
RB71 PSY
UP