Closed as program error.
Error description
When you use IBM Business Process Manager (BPM) V8.5.7 federated with IBM Process Federation Server and interim fix JR50481 is installed on the federated environment, you cannot complete the following actions in IBM Process Portal: -Navigating to a business process definition (BPD) from the Process Performance dashboard for the federated IBM BPM environment. -Viewing the Gantt chart for a process instance on the federated IBM BPM environment. PRODUCTS AFFECTED IBM BPM Advanced IBM BPM Standard IBM BPM Express
Local fix
Problem summary
The navigation controller in the System Dashboards toolkit on the federated IBM BPM system checks the value of the launchInNewWindow configuration property, which was introduced with interim fix JR50481. That check sends an exception if Process Portal is hosted on a different IBM BPM system than where the toolkit is hosted, which is often the case in a federated environment. The exception prevents the Gantt chart from loading in Process Portal.
Problem conclusion
A fix that catches an exception in the check for the launchInNewWindow property and assumes the property is set to false, allowing the Gantt chart to load successfully in Process Portal, is available in IBM BPM V8.5.7.0.
Temporary fix
Not applicable
Comments
APAR Information
APAR number
JR55622
Reported component name
BPM ADVANCED
Reported component ID
5725C9400
Reported release
857
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-03-25
Closed date
2016-04-18
Last modified date
2016-04-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BPM ADVANCED
Fixed component ID
5725C9400
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSFTN5","label":"IBM Business Process Manager Advanced"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"857","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
18 April 2016