Error description
When using BPMConfig command line utility, BPMConfig will check that BPC should not share database schema with ProcessServer or EmbeddECM, but in DE wizard path, BPM does not provide such check, this will cause potential issue, if customer use DE wizard to create deployment environments. CWMCB0299E: Components ProcessServer and BPC cannot share the same database schema ('BPMDBA' in database Oracle). CWMCB0299E: Components EmbeddedECM and BPC cannot share the same database schema ('BPMDBA' in database Oracle).
Local fix
Either manually check on the DE wizard page to make sure that BPC does not use same database schema with ProcessServer or use BPMConfig command utility to create deployment environment.
Problem summary
ADD VALIDATE FOR DE WIZARD PATH TO CHECK COMPONENTS BPC AND PROCESSSERVER/EMBEDDECM CAN NOT SHARE THE SAME DB SCHEMA
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
JR55604
Reported component name
BPM ADVANCED
Reported component ID
5725C9400
Reported release
856
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-03-23
Closed date
2016-03-31
Last modified date
2016-03-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
R856 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSFTN5","label":"IBM Business Process Manager Advanced"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"856","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
31 March 2016