Fixes are available
APAR status
Closed as fixed if next.
Error description
The error occurs in situations where you create multiple decisions services, as in the following steps: 1. Create two decision services "d1" and "d2". Specify two outputs for each, "d1_yes", "d1_no", "d2_yes", and "d2_no", respectively. 2. Create a business process definition (BPD) named "Testing Decisions". 3. Add two decision gateways to the BPD, "g1" and "g2". 4. For "g1", select "d1" as the decision service under the "Decision" property; do the same for "g2" and "d2". 5. Notice that when using tw.decision, you only see the "d1" or "d2" output variables available in auto completion, not both. PRODUCTS AFFECTED: IBM Business Process Manager (BPM) Advanced IBM BPM Standard IBM BPM Express
Local fix
A workaround for this is to not directly switch to gateway 2, but deselect gateway 1 first (by clicking anywhere on the diagram) and then select gateway 2 (this forces UI widgets to reload).
Problem summary
The UI does not get updated properly when switching from one gateway to a second one when both of them have the same number of outgoing flows. The system thinks it does not need to reload the widgets (so the JS autocomplete feature shows old variables). A fix will be incorporated into a later release that will make sure widgets are properly reloaded when switching from one gateway to any other one. This will properly update JavaScript autocompletion.
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
JR50245
Reported component name
BPM STANDARD
Reported component ID
5725C9500
Reported release
751
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-05-14
Closed date
2014-07-29
Last modified date
2014-07-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
R751 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSFTDH","label":"IBM Business Process Manager Standard"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.1","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
14 October 2021