Fixes are available
APAR status
Closed as program error.
Error description
Performance issues in COM.LOMBARDISOFTWARE.SERVER.CORE.SYMBOLTABLE functions
Local fix
%
Problem summary
Performance tests have revealed that a high number of CPU instructions are spent in class com.lombardisoftware.server.core.SymbolTable. PROBLEM DETAILED DESCRIPTION: Within class com.lombardisoftware.server.core.SymbolTable the usage of String.toUpperCase() has caused the high number of CPU instructions.
Problem conclusion
With this interim fix the usage of String.toUpperCase() in class com.lombardisoftware.server.core.SymbolTable will be optimized to reduce the CPU load caused by this class. FIX AVAILABILITY: iFix for 8.0.1.2 is/will be available on Fix Central; search for APAR JR48900 at http://www.ibm.com/support/fixcentral/ Fix is also targetted for inclusion in next fixpack for BPM 8.0.1 When obtaining any of the above fixes, be sure to download the accompanying readme, for itself, and any prerequisite fixes, and review them thorougly.
Temporary fix
Comments
APAR Information
APAR number
JR48900
Reported component name
BPM STANDARD
Reported component ID
5725C9500
Reported release
801
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-12-20
Closed date
2014-02-25
Last modified date
2014-02-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BPM STANDARD
Fixed component ID
5725C9500
Applicable component levels
R801 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSFTDH","label":"IBM Business Process Manager Standard"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.1","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
11 October 2021