Error description

  • When a process application contains a parent business process
    definition (BPD) that calls a linked sub-process BPD that is
    defined in a toolkit, then monitoring events are not emitted
    from the linked sub-process.  The result is that default KPIs
    that Business Process Manager provides are not populated with
    values.  Note that this issue is specific to a linked
    sub-process BPD that is defined in a toolkit.  If the linked
    sub-process BPD and the parent BPD are both associated with
    the same process application, then the issue does not occur.
    

Local fix

  • Refactoring the application so that a linked sub-process BPD is
    included in the same process application as the parent BPD
    rather than in a toolkit will result in values for default KPIs.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  Users of BPM Express, BPM Standard, and     *
    *                  BPM Advanced.                               *
    ****************************************************************
    * PROBLEM DESCRIPTION: Monitoring events are not emitted       *
    *                      from a linked sub-process BPD when      *
    *                      the linked sub-process is defined       *
    *                      within a toolkit.                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Logic to retrieve the execution context searched at the level
    of the toolkit rather than the level of the process
    application associated with the calling BPD.
    

Problem conclusion

  • Logic to retrieve the execution context was revised to search
    at the level of the process application associated with the
    BPD that called the linked sub-process.
    
    An interim fix has been created for IBM Business Process
    Manager version 8.0.1.1.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR48215

  • Reported component name

    BPM ADVANCED

  • Reported component ID

    5725C9400

  • Reported release

    800

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-10-24

  • Closed date

    2013-12-16

  • Last modified date

    2013-12-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    BPM ADVANCED

  • Fixed component ID

    5725C9400

Applicable component levels

  • R800 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSFTN5","label":"IBM Business Process Manager Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
12 October 2021