  • If Blackout calenders are defined using Weekday / Time range
    while daylight saving time is active, the begin and end of the
    blackout period is scheduled with 1 hour difference to the
    definition.
    

Local fix

  • n/a
    

Problem summary

  • Problem Description:
    If Blackout calenders are defined using Weekday / Time range
    while daylight saving time is active, the begin and end of the
    blackout period is scheduled with 1 hour difference to the
    definition.
    
    Problem Summary:
    The problem is caused by usage of the browser's timezone, which
    does not respect DST, but rather moves the Timezone by 1 hour
    if DST is active.
    

Problem conclusion

  • Refrain from using the browser's timezone if Weekday / Time
    range is specified in the blackout schedule.
    
    FIX AVAILABILITY:
    iFix for 8.0.1.0 is available on Fix Central, search for APAR
    JR47094 at http://www.ibm.com/support/fixcentral/
    iFix for 8.0.1.1 is available on Fix Central, search for APAR
    JR47094 at http://www.ibm.com/support/fixcentral/
    Fix is also included in 8.0.1.2
    Fix is also included in 8.5.0.1
    
    When obtaining any of the above fixes, be sure to download the
    accompanying readme, for itself and any prerequisite fixes, and
    review them thorougly.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR47094

  • Reported component name

    BPM STANDARD

  • Reported component ID

    5725C9500

  • Reported release

    801

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-06-28

  • Closed date

    2013-08-15

  • Last modified date

    2013-08-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    BPM STANDARD

  • Fixed component ID

    5725C9500

Applicable component levels

  • R801 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSFTDH","label":"IBM Business Process Manager Standard"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.1","Edition":"","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]