IBM Support

JR47090: CMVC 229212 - FACET.SEQUENCE does not get updated with the sequence set in Commerce Management Center (CMC)

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • In the CMC Catalog Tool, update the sequence of the attributes
    in the Catalog Asset Store - Attribute Dictionary - Attributes
    List.
     FACET.SEQUENCE does not get updated in the database and when a
    search is done in the storefront, the search results page will
    not show the correct sequence (the sequence is fine on
    Categories pages).
    

Local fix

  • Manually update the FACET.SEQUENCE in the database
    

Problem summary

  • USERS AFFECTED:
     WebSphere Commerce v7 users with AuroraESites who wish to
    change the default sequence of facets
    
     PROBLEM ABSTRACT:
     FACET.SEQUENCE does not get updated with the sequence set in
    Commerce Management Center (CMC)
    
     BUSINESS IMPACT:
     End users will not see the intended sequence of the facets
    
     RECOMMENDATION:
    

Problem conclusion

  • An update is done to the FACET.SEQUENCE column when the sequence
     is changed in CMC
     -------------------------------------------------------------
     The latest available maintenance information can be obtained
    from the Recommended Fixes for WebSphere Commerce technote:
     http://www.ibm.com/support/docview.wss?rs=3046&uid=swg21261296
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR47090

  • Reported component name

    WC BUS EDITION

  • Reported component ID

    5724I3800

  • Reported release

    700

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-06-27

  • Closed date

    2013-11-05

  • Last modified date

    2013-11-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WC BUS EDITION

  • Fixed component ID

    5724I3800

Applicable component levels

  • R700 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSYSYL","label":"WebSphere Commerce Enterprise"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: