Error description
When using Unicode characters in your business processes and the operating system locale does not support Unicode, UCA input/output parameters may be corrupted. When scheduling an UCA, the parameters are stored in the database after converting to a byte array using the system's default encoding. This conversion may corrupt the parameters when containing characters the system's default encoding does not support.
Local fix
n/a
Problem summary
When using Unicode characters in your business processes and the operating system locale does not support Unicode, UCA input/output parameters may be corrupted. PROBLEM DETAILED DESCRIPTION: When scheduling an UCA, the parameters are stored in the database after converting to a byte array using the system's default encoding. This conversion may corrupt the parameters when containing characters the system's default encoding does not support.
Problem conclusion
The fix uses UTF-8 encoding to solve the problem. For running instances the problem might occur further. FIX AVAILABILITY: Fix is targetted for inclusion in next fixpack for BPM 8.0.1, BPM 8.5.0 When obtaining any of the above fixes, be sure to download the accompanying readme, for itself and any prerequisite fixes, and review them thorougly.
Temporary fix
Comments
APAR Information
APAR number
JR46995
Reported component name
BPM ADVANCED
Reported component ID
5725C9400
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-06-18
Closed date
2013-10-02
Last modified date
2013-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BPM ADVANCED
Fixed component ID
5725C9400
Applicable component levels
R850 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSFTN5","label":"IBM Business Process Manager Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
08 January 2022