Error description
Rename a folder in DataStage Designer. Old folder still remains in DataStage Director and a new folder shows up with the renamed name
Local fix
Problem summary
**************************************************************** USERS AFFECTED: Users renaming folders in designer **************************************************************** PROBLEM DESCRIPTION: If a folder is renamed in the designer then the director continues to display the old folder name. It also loses track of some of the compiled jobs in folder further down the tree. This is caused by a failure to keep the xmeta (design time) repository in synch with the runtime repository stored in engine hash files. **************************************************************** RECOMMENDATION: Install APAR JR47525 (which includes this fix) The patch should be applied to rectify the interaction between the designer and client. ****************************************************************
Problem conclusion
The problem was resolved by changing the client to have it request the folder name for each job which exists in the renamed folder or below it in the folder tree.
Temporary fix
The old folder name can be deleted manually from the DS_JOBS file on the server and the director display corrected asmentioned in the circumvention.
Comments
APAR Information
APAR number
JR46806
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
910
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-06-03
Closed date
2013-07-16
Last modified date
2013-09-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
R910 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"InfoSphere DataStage"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.1","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
16 October 2021