Fixes are available
APAR status
Closed as program error.
Error description
When the body of a message passed between SCA modules contains a modeled fault, an exception similar to the following may occur: javax.transaction.TransactionRolledbackException: CORBA TRANSACTION_ROLLEDBACK 0x0 No; nested exception is: org.omg.CORBA.TRANSACTION_ROLLEDBACK: javax.transaction.TransactionRolledbackException: ; nested exception is: javax.ejb.EJBException: nested exception is: java.lang.ClassCastException: com.ibm.ws.box.bomodel.impl.BusinessObjectImpl incompatible with org.eclipse.emf.ecore.sdo.EDataObject vmcid: 0x0 minor code: 0 completed: No
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Business Process Manager Users * **************************************************************** * PROBLEM DESCRIPTION: When the body of a message passed * * between SCA modules contains a * * modeled fault, a ClassCastException * * may occur. * **************************************************************** * RECOMMENDATION: * **************************************************************** The ClassCastException is result of Advanced Integration Service SCA layer's inability to correctly handle modeled faults with complex types. The code works as expected when fault is modeled as simple type.
Problem conclusion
The fix provided will correctly handle faults modeled as complex types. Install/Dependency information is available in the readme.txt on FixCentral. When the user goes to the download files page in FixCentral, the readme will be available with the fix package as a separate download.
Temporary fix
Comments
APAR Information
APAR number
JR46709
Reported component name
BPM ADVANCED
Reported component ID
5725C9400
Reported release
801
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-05-20
Closed date
2013-07-31
Last modified date
2013-07-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BPM ADVANCED
Fixed component ID
5725C9400
Applicable component levels
R750 PSY
UP
R800 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSFTN5","label":"IBM Business Process Manager Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.1","Line of Business":{"code":"LOB45","label":"Automation"}}]