Error description
When calling an Advanced Integration Service (AIS) with datetime attribute, the milliseconds are gone when reaching the client. The Client receives the datetime variable without milliseconds. The milliseconds are set to "000". The same behavior occurs also backwards, when sending a datetime field from any module with SCA binding to the process application, the milliseconds are omitted, too.
Local fix
n/a
Problem summary
For requests and responses sent to and received from advanced integration services (AIS), dateTime and time values are loosing their millisecond part. This interim fix enables to preserve the millisecond part.
Problem conclusion
To enable preserving the milliseconds for requests and reponses to and from AIS, add the following to your 100Custom.xml configuration file and restart the servers: <properties> <server> ... <preserve-milliseconds-for-ais>true</preserve-milliseconds-for-a is> ... </server> </properties> Problem will be fixed with V8501
Temporary fix
Comments
APAR Information
APAR number
JR46507
Reported component name
BPM ADVANCED
Reported component ID
5725C9400
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-04-30
Closed date
2013-08-14
Last modified date
2013-08-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BPM ADVANCED
Fixed component ID
5725C9400
Applicable component levels
R850 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSFTN5","label":"IBM Business Process Manager Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
08 January 2022