Error description

  • Error in BO Mapping when 2 top level objects are used as the
    input to a submap.
    
    
    The second nested submap call fails with the error:
    
    [11/8/12
    21:41:23:125 CST] 00000075 BaseMapUtils  E MapIt  Transformation
    #1()
    CWLAS0015E: The Submap transform #1 in the MapIt map did not
    complete
    because of the following exception: CWLAS0015E: The Submap
    transform #2
    in the Sub1 map did not complete because of the following
    exception:
    CWSDO0035E: The following SDO path could not be evaluated:
    Parent_BO_Input.
    

Local fix

  • Submaps can be redesigned such that they only map
    sub-components(children only) or use at most only 1 top level
    object as input.
    
    This will avoid errors.
    
    
    Otherwise,
    This APAR will resolve the problem.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  Business Process Manager v7.5 users         *
    ****************************************************************
    * PROBLEM DESCRIPTION: BO map failed when setting two top      *
    *                      level object as submap inputs           *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The second nested BO submap call fails when 2 top level
    objects are used as the input to a submap.
    [11/8/12 21:41:23:125 CST] 00000075 BaseMapUtils  E MapIt
    Transformation #1() CWLAS0015E: The Submap transform #1 in the
    MapIt map did not complete because of the following exception:
    CWLAS0015E: The Submap transform #2 in the Sub1 map did not
    complete because of the following exception: CWSDO0035E: The
    following SDO path could not be evaluated: Parent_BO_Input.
    

Problem conclusion

  • The problem is fixed by re-design submap implementation to
    support more than one top level object.
    
    Install/Dependency information is available in the readme.txt
    on FixCentral. When the user goes to the download files page
    in FixCentral, the readme will be available with the fix
    package as a separate download.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR45907

  • Reported component name

    BPM ADVANCED

  • Reported component ID

    5725C9400

  • Reported release

    751

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-03-01

  • Closed date

    2013-03-19

  • Last modified date

    2013-03-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    BPM ADVANCED

  • Fixed component ID

    5725C9400

Applicable component levels

  • R750 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSFTN5","label":"IBM Business Process Manager Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.1","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
08 January 2022