Error description

  • In a correct BPMN process, a timeout event on an activity is
    always connected to a follow-on node. If this connection
    is missing, the BPMN model is invalid. In BPM 8.0.0, a
    validation has been introduced to reject such invalid models.
    This APAR will remove the validation again.
    

Local fix

  • N/A
    

Problem summary

  • Problem Description:
    A TeamWorksException is thrown stating 'no outgoing sequence
    flows are defined or all sequence flow conditions evaluated to
    "false".'
    
    
    Problem Summary:
    Timeout events on activities must be connected to other nodes.
    If these connectors are missing, the BPMN model is invalid.
    Thus, BPM 8.0.1 will throw an exception.
    However, in BPM 7.5.x, the missing connectors causes the timeout
    event to be ignored.
    
    
    Problem Conclusion:
    With this fix, the timeout event is ignored again if the
    connector is missing.
    

Problem conclusion

  • Problem fixed
    iFix available on top of V801 GA
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR45047

  • Reported component name

    BPM STANDARD

  • Reported component ID

    5725C9500

  • Reported release

    801

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-12-06

  • Closed date

    2013-01-07

  • Last modified date

    2013-01-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    BPM STANDARD

  • Fixed component ID

    5725C9500

Applicable component levels

  • R801 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSFTDH","label":"IBM Business Process Manager Standard"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.1","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
11 October 2021