Error description

  • When loading a descriptive attribute with allowed value to a
    catalog entry using the
    CatalogEntryAttributeDictionaryAttributeRelationship load item,
    an option is needed to automatically initialize the allowed
    value if it does not already exist.
    

Local fix

Problem summary

  • USERS AFFECTED:
    Business users loading product attributes into the attribute
    dictionary and associating them to a product.
    
    PROBLEM ABSTRACT:
    When loading a descriptive attribute with allowed value to a
    catalog entry using the
    CatalogEntryAttributeDictionaryAttributeRelationship load item,
    there is no way to automatically initialize the allowed value if
    it does not exist.
    
    BUSINESS IMPACT:
    Additional steps are required to initialize an attribute allowed
    value for a catalog entry.
    
    RECOMMENDATION:
    

Problem conclusion

  • Added support to the dataload mediator to automatically
    initialize an allowed value if initAttribute property is set to
    "true".
    <_config:property name="initAttribute" value="true" />
    
    
    -------------------------------------------------------------
    The latest available maintenance information can be obtained
    from the Recommended Fixes for WebSphere Commerce technote:
    http://www.ibm.com/support/docview.wss?rs=3046&uid=swg21261296
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR44791

  • Reported component name

    WC BUS EDITION

  • Reported component ID

    5724I3800

  • Reported release

    700

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-11-16

  • Closed date

    2013-05-30

  • Last modified date

    2013-05-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WC BUS EDITION

  • Fixed component ID

    5724I3800

Applicable component levels

  • R700 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSYSYL","label":"WebSphere Commerce Enterprise"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
30 May 2013