Fixes are available
APAR status
Closed as program error.
Error description
Upgrade 6x tool falls into a loop when creating DB schema on the customer side since the settings in resource.xml are incorrect.
Local fix
Override the settings in the configuration file manually.
Problem summary
**************************************************************** * USERS AFFECTED: Business process manager V7.5 users * **************************************************************** * PROBLEM DESCRIPTION: The upgrade 6x tool falls into a loop * * in DB schema creating step caused by * * incorrect port set in resource.xml. * **************************************************************** * RECOMMENDATION: * **************************************************************** This issue is caused by the generated resource.xml which includes an he incorrect port number to be used to connect to the database. Using the incorrectly generated port, the connection to the database fails and subdequently the DB schema creation also fails. The upgrade_6x tool will then retry the schema creationg step and falls into an infinite loop.
Problem conclusion
The ifix fixes the incorrectly generated port number of the resource.xml. The correct port is now generated and the shcema creation step completes successfully. Install/Dependency information is available in the readme.txt on FixCentral. When the user goes to the download files page in FixCentral, the readme will be available with the fix package as a separate download The ifix can be downloaded in the fix central
Temporary fix
Comments
APAR Information
APAR number
JR44704
Reported component name
BPM ADVANCED
Reported component ID
5725C9400
Reported release
751
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-11-12
Closed date
2013-01-22
Last modified date
2013-01-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BPM ADVANCED
Fixed component ID
5725C9400
Applicable component levels
R750 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSFTN5","label":"IBM Business Process Manager Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.1","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
12 October 2021