Error description
If a job contains 3 or more Java connector stages, and has multiple instances of a particular stage type, then initialization can fail in the conductor node. For example, consider a job containing 3 stages: JavaConnectorA(Stage1) --> JavaConnectorB(Stage 2) --> JavaConnectorA(Stage 3) When such a job is started, rather than an instance of JavaConnectorA be created for Stage 3, instead, an instance of JavaConnectorB is created for Stage 3. This results in a property set error, such as: com.ascential.e2.common.CC_Exception: Required property not set: /Usage/E2Assembly
Local fix
Problem summary
If a job contains 3 or more Java connector stages, and has multiple instances of a particular stage type, common connector framework does not update JNI references properly. As result, initialization fails in the conductor node.
Problem conclusion
Modified common connector framework modules for Java-based connector stages.
Temporary fix
Comments
APAR Information
APAR number
JR44601
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
910
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-10-31
Closed date
2013-05-23
Last modified date
2013-05-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
R910 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"IBM InfoSphere DataStage"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
23 May 2013