IBM Support

JR44490: CEI EVENT-EMITTING MICROFLOWS LEAVE 'ORPHAN' RECORDS IN BPEDB

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When CEI common base event (CBE) emission is enabled on a BPEL
    process, an event counter table (PROGRESS_COUNTER_T) keeps
    track of the sequence of events that each process instance
    emits. Records in this database table should get deleted, when
    the associated process instance gets deleted. For microflows
    this does not work, i.e. an 'orphan' record for each deleted
    microflow remains in the table.
    

Local fix

Problem summary

  • CEI event-emitting microflows leave 'orphan' records in BPEDB.
    

Problem conclusion

  • Progress counter records are no longer be persisted for
    microflows.
    

Temporary fix

  • Not applicable
    

Comments

APAR Information

  • APAR number

    JR44490

  • Reported component name

    BPM ADVANCED

  • Reported component ID

    5725C9400

  • Reported release

    751

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-10-23

  • Closed date

    2015-02-06

  • Last modified date

    2015-02-06

  • APAR is sysrouted FROM one or more of the following:

    IV30705

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    BPM ADVANCED

  • Fixed component ID

    5725C9400

Applicable component levels

  • R751 PSN

       UP

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSFTN5","label":"IBM Business Process Manager Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.1"}]

Document Information

Modified date:
07 October 2021