Error description

  • In the BPD, there is a Tracking Intermediate Event has no
    Tracking Group assigned, that causes incomplete Timing Interval
    definition. Then user sends tracking definitions to PDW, will
    get NPE errors:
    
    Caused by: com.lombardisoftware.core.TeamWorksException:
    java.lang.NullPointerException
     at
    com.lombardisoftware.core.TeamWorksException.asTeamWorksExceptio
    n(TeamWo
    rksException.java:130)
     at
    com.lombardisoftware.server.tracking.loader.LoaderStrategy.resum
    eLoad(Lo
    aderStrategy.java:122)
     at
    com.lombardisoftware.server.tracking.definitionloader.Definition
    LoaderSt
    rategy.resumeLoad(DefinitionLoaderStrategy.java:64)
     at
    com.lombardisoftware.server.ejb.tracking.DataDefLoaderCore.onMes
    sage(Dat
    aDefLoaderCore.java:42)
     ... 33 more
    Caused by: java.lang.NullPointerException
     at
    com.lombardisoftware.server.tracking.definitionloader.LoadVisito
    r.visit(
    LoadVisitor.java:1004)
     at
    com.lombardisoftware.server.tracking.definitionloader.TrackingDe
    finition
    Traverser.traverseBounds(TrackingDefinitionTraverser.java:351)
     at
    com.lombardisoftware.server.tracking.definitionloader.TrackingDe
    finition
    Traverser.traverse(TrackingDefinitionTraverser.java:333)
    

Local fix

  • In the Timing Inverval definitions, make sure all start and end
    points have a Tracking Group assigned before sending tracking
    definitions to Performance Data Warehouse.
    

Problem summary

  • Fix delivery scheduled for next V8 release, targetting 4Q2012.
    

Problem conclusion

Temporary fix

  • See LOCAL FIX.
    

Comments

APAR Information

  • APAR number

    JR43508

  • Reported component name

    BPM ADVANCED

  • Reported component ID

    5725C9400

  • Reported release

    751

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-07-20

  • Closed date

    2012-09-11

  • Last modified date

    2012-09-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

  • R800 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSFTN5","label":"IBM Business Process Manager Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.1","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
12 October 2021