JR42894: COACH OUTPUT TEXT BOX DOES NOT DISPLAY HTML FORMATTING

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • After applying APAR JR42280, an output text box in a coach does
    not display HTML formatting.  For example, if <b> and </b> tags
    are used to specify bold text, the actual tags are rendered in
    the coach.  The expected result is that the formatting
    specified by the tags will be displayed instead of the tags
    themselves.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  Users of BPM Express, BPM Standard, and     *
    *                  BPM Advanced.                               *
    ****************************************************************
    * PROBLEM DESCRIPTION: An output text box in a coach does      *
    *                      not display HTML formatting.            *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Apply the fix for JR42894 which is available from Fix Central.
    JR42894 makes changes to escape JavaScript and HTML
    configurable
    for an output text box.  An "Escape HTML And JavaScript Code"
    check box has been added to Properties > Presentation section
    in
    Process Designer for an output text box.  Checking the "Escape
    HTML And JavaScript code" check box will result in escaped
    JavaScript and HTML in the output text box.  The default
    setting
    for an output text box is to not escape content, so explicitly
    checking the "Escape HTML And JavaScript Code" check box should
    be used when content displayed is based on input that is not
    tightly controlled by the application itself; this will prevent
    unintended JavaScript from being executed.  In cases where the
    output text box is being used to display HTML, then the "Escape
    HTML And JavaScript Code" check box can be unchecked so that
    HTML formatting will render in the output text box.  To limit
    the possibility of unintended JavaScript execution when
    unchecking the "Escape HTML And JavaScript Code" check box,
    care
    should be taken that the application tightly controls what will
    be displayed in the output text box.
    

Problem conclusion

  • The fix for JR42894 is available on Fix Central for the
    7.5.1.0 level of IBM Business Process Manager.
    
    The JR42894 package available on Fix Central has two parts,
    one for the runtime (supporting Process Server and Process
    Center profiles) and one for Process Designer.  The file for
    the runtime has "BPM" in the name and the file for Process
    Designer has "BPMPD" in the name.  If the runtime fix is
    applied to an environment that supports Process Center, then
    the Process Designer fix (with "BPMPD" in the name) needs to
    be applied to every Process Designer that connects to that
    Process Center, otherwise there will be a version mismatch.
    
    
    7.5.1.0 prerequisite information and installation order:
    
    Please note that JR42576 and JR42765 are server prerequisite
    interim fixes fo rJR42894.  The Process Designer JR42894
    interim fix does not have prerequisites.
    
    Following is the interim fix installation order: JR42012,
    JR42280, JR42220, JR42232, JR42330, JR42342, JR42576, JR42331,
    JR42452, JR42765, and JR42894.
    
    
    Installation instructions for 7.5.1.0:
    
    To install the JR42894 interim fix, follow these steps.
    1.  Backup the BPM and Performance Data Warehouse databases.
    2.  Backup a stand-alone profile or all profiles in a network
    deployment environment.  The "backupConfig" command can be
    used to backup a profile.  See the following documentation
    section:
    http://pic.dhe.ibm.com/infocenter/wasinfo/v7r0/index.jsp?topic=/
    com.ibm.websphere.nd.multiplatform.doc/info/ae/ae/rxml_backupcon
    fig.html
    3.  Stop a stand-alone server or network deployment
    environment before applying any fix.
    4.  Install the JR42894 runtime and Process Designer interim
    fix packages using IBM Installation Manager.  Prerequisite
    fixes and other fixes in the installation order can be
    installed at the same time as JR42894.
    5.  Upgrade profiles:
    - For a stand-alone environment, follow step two in this
    section:
    http://publib.boulder.ibm.com/infocenter/dmndhelp/v7r5m1/topic/c
    om.ibm.wbpm.imuc.doc/topics/tmig_upgrading_bpm_errors.html
    - For a network deployment environment, follow step three in
    this section for each cluster:
    http://publib.boulder.ibm.com/infocenter/dmndhelp/v7r5m1/topic/c
    om.ibm.wbpm.imuc.doc/topics/tmig_upgrading_bpm_nd_clusters.html
    6.  Run the upgrade_7x command to update the database by
    following step one in this section:
    http://publib.boulder.ibm.com/infocenter/dmndhelp/v7r5m1/topic/c
    om.ibm.wbpm.imuc.doc/upgrade/topic/upgrading_existing_dbs_751.ht
    ml
    7.  Start the stand-alone server or network deployment
    environment.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR42894

  • Reported component name

    BPM ADVANCED

  • Reported component ID

    5725C9400

  • Reported release

    750

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-05-18

  • Closed date

    2012-08-10

  • Last modified date

    2012-08-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    BPM ADVANCED

  • Fixed component ID

    5725C9400

Applicable component levels

  • R750 PSY

       UP