IBM Support

JR42876: RESTART POSITION DOES NOT MOVE FORWARD WHEN WE SEE EMPTY TRANSACTIONS.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • There is an optimization in LogReader to throw away empty
    transactions. However, when there is an empty transaction, CDC
    may incorrectly send the begin transaction to the parser, but
    not the commit transaction.
    
    The net effect is that restart position will not move forward.
    

Local fix

Problem summary

  • The restart position in the bookmark may remain
    pinned at a given LSN and not move forward. The
    most common symptom of this issue is a
    subscription failing because it cannot locate
    the LSN at startup, despite having minimal
    latency. Below is an example of this type of
    error:
    "ID:                9602
    Detail:            An exception has occurred
    during mirroring.
    Error: Failed to activate informix session. The LSN is
    <LSN-VALUE> and the corresponding logical log uniqid is
    <UNIQID-VALUE>.
    Error Message: Data at the requested log sequence number is not
    available for capture.
    Possible Cause: The LSN is no longer in online logs.
    In this case the UniqID belongs to a log which has long been
    archived or removed.
    

Problem conclusion

  • Please apply the following interim fix to
    address this issue.
    ISCDC 6.5.1 InterimFix 6 For Informix
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR42876

  • Reported component name

    INFOSPH CHG DTA

  • Reported component ID

    5724U7000

  • Reported release

    651

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-05-18

  • Closed date

    2012-07-18

  • Last modified date

    2012-07-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • CDCAPAR
    

Fix information

  • Fixed component name

    INFOSPH CHG DTA

  • Fixed component ID

    5724U7000

Applicable component levels

  • R651 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSX3HK","label":"InfoSphere Change Data Capture"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"651","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: