IBM Support

JR42860: P.E. IMPORTING A PROCESS APP THAT HAS SMART FOLDERS IN IT WILL FAIL IF JR42012 IS INSTALLED and OTHER REGRESSION FROM JR42012.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • There were two regressions that were found after installing
    JR42012:
    
    1. If JR42012 is installed, WSDL discovery will not work for
    "recursive XSD files", i.e when an XML schema tries to import
    itself. WSDL discovery works in general.
    
    2. On an Environment where JR42012 is installed, A Process
    Application that has Smart Folders in it, will fail to
    import in Process Center.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  BPM 7.5 Express, Standard and               *
    *                  Advanced USERS WHO HAVE INSTALLED JR42012   *
    ****************************************************************
    * PROBLEM DESCRIPTION: There were two regressions that were    *
    *                      found after installing                  *
    *                      JR42012:                                *
    *                      1. If JR42012 is installed, WSDL        *
    *                      discovery will not work for             *
    *                      "recursive XSD files", i.e when an      *
    *                      XML schema tries to import itself.      *
    *                      WSDL discovery works in general.        *
    *                      2. On an Environment where JR42012 is   *
    *                      installed, A Process Application that   *
    *                      has Smart Folders in it, will fail to   *
    *                      import in Process Center.               *
    ****************************************************************
    * RECOMMENDATION:  If you already have JR42012 installed and   *
    *                  experience one of the above problems then   *
    *                  install JR42860.                            *
    *                  If you do not have JR42012 installed then,  *
    *                  downloading and installing the current      *
    *                  JR42012 will fix the above problems.        *
    *                  JR42860 does not need to be installed in    *
    *                  that case. (even if it is installed it      *
    *                  will only re-install the fixes)             *
    ****************************************************************
    1. If JR42012 is installed, WSDL discovery will not work for
    "recursive XSD files", i.e when an XML schema tries to import
    itself.
    On Discovery, user will see an error:
    src-import.1.1 &#175;   &#161;<import>  item info namespace
    property &#162;&#226;&#130;&#172; &#147;http://schemas.xmlsoap.org/soap/encoding/ &#162;&#226;&#130;&#172;  &#189;
    not
    be the same as the targetNamespace of the schema it resides.
    WSDL discovery works in general.
    2. On an Environment where JR42012 is installed, A Process
    Application that has Smart Folders in it, will fail to import
    in Process Center.
    

Problem conclusion

  • The above problems were there because of missing/corrupt
    classes (which were replaced) and because of the missing fix to
    recursive XSDs.
    
    The Problems are fixed in JR42860 available on fix central.
    JR42860 can be applied on top of existing installed JR42012.
    
    Installing JR42860 on top of a JR42012 that does not exhibit
    these error conditions will have no effect, detrimental or
    otherwise.
    
    The fixes were also backported to JR42012 and the package
    replaced on fix central. (May 18). If customer installs new
    JR42012 then installing JR42860 will just replace the same
    classes.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR42860

  • Reported component name

    BPM STANDARD

  • Reported component ID

    5725C9500

  • Reported release

    751

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-05-16

  • Closed date

    2012-05-18

  • Last modified date

    2012-05-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    BPM STANDARD

  • Fixed component ID

    5725C9500

Applicable component levels

  • R750 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSFTDH","label":"IBM Business Process Manager Standard"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
18 May 2012