IBM Support

JR42631: UNABLE TO TEST WEB SERVICES WITH A EMPTY RESPONSE ELEMENT

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as fixed if next.

Error description

  • When selecting variables to show in BPEL FGT, if any selected
    are interface variables rather than data type variables, an
    exception will occur when trying to display the FGT events.
    Similarly, an exception will occur when creating a Verify event
    for activities with BPEL interface variables.
    

Local fix

  • The user can close the exception dialog and switch to the XML
    view to see the data, or they can choose to not show the
    interface variables (this requires looking at each variable
    definition in the BPEL editor to determine which are interface
    variables). If the user wants to create a test case verification
    event, they need to verify an event other than a BPEL FGT event
    (may or may not be acceptable as a workaround, depending on the
    scenario).
    

Problem summary

  • Fix delivery planned for future IID 7.5.1 and 8.0 cumulative
    maintenance/release deliverables, targetting 2H2012, and WID 7.0
    cumulative maintenance deliverable, targetting 2Q2012.
    
    Fix will check that BPEL variables have an XSD type wherever
    they are encountered in the comptest code. If not, we ignore
    them so that no errors occur and the values show up as expected
    in the SDO and XML views, and test case verification events can
    be created (but that don't include the variables we can't
    verify).
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    JR42631

  • Reported component name

    INTEGRATION DES

  • Reported component ID

    5725C9702

  • Reported release

    750

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-04-25

  • Closed date

    2012-06-20

  • Last modified date

    2012-06-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

  • R751 PSY

       UP

  • R800 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSTLXK","label":"IBM Integration Designer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
20 June 2012