A fix is available
APAR status
Closed as program error.
Error description
Parallel job containing and ODBC Enterprise stage aborts when a column with data type BIGINT has the Unsigned extended property set. The status Fatal message which appears in the job log: Message:: dbProcessTableLastValue,0: Internal Error: (0): odbc_upsert_subop.C: 1332 This issue is reproducible with both Information Server Version 8.0.1 FP1 and Version 8.1, using SQL Server 2005 as the target and using the 5.3 DataDirect ODBC driver. Problem was reproduced on both AIX and Windows platforms using these software versions, but may occur in other combinations as well. There is no warning message logged indicating the type mismatch with unsigned.
Local fix
Remove the unsigned extended attribute from the BIGINT column (assuming the datatype is not actually unsigned.)
Problem summary
**************************************************************** USERS AFFECTED: All users of ODBC Enterprise Stage where unsigned extended property is set for BIGINT field in the columns tab **************************************************************** PROBLEM DESCRIPTION: When BIGINT field contains Unsigned extended property in a ODBC EE Write / Update job, the job fails with the following error message: Message:: dbProcessTableLastValue,0: Internal Error: (0): odbc_upsert_subop.C: 1332 Which is not meaningful. **************************************************************** RECOMMENDATION: Local fix: Remove the "unsigned" extended property from the columns tab for the BIGINT field Apply a latest ODBC EE Patch build time later than 29th March, 2010 ****************************************************************
Problem conclusion
Throw a meaningful error message including the field name when the datatype/ extended arrtibute is not supported.
Temporary fix
Comments
APAR Information
APAR number
JR36083
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
801
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-03-26
Closed date
2010-03-29
Last modified date
2010-03-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
R801 PSN
UP