IBM Support

JR35970: IS 8.0.1: TERADATA CONNECTOR PX STAGE DOES NOT ALLOW VARIANT 12 TO BE SELECTED IN DROP-DOWN RESULTING IN FAILED BULK LOAD.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • After upgrading TeraData from v8 to v12, the TeraData Connector
    PX stage fails and v12 is not available in the Variant drop-down
    combo box.  Variant 12 must be selected for running in bulk
    mode.
    

Local fix

  • Set Access Mode to Immediate to work around issue, however
    performance will be noticably poorer.
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    TDEE users running with "tenacity" & "sleep" options on
    multi-node config & encounter 2633 error from TD-DBS.
    ****************************************************************
    PROBLEM DESCRIPTION:
    Issue with tenacity-option, when running on multi-node config &
    player processes do not get any sessions to
    report-session-error. (This only happens when DBS is under max.
    load).
    ****************************************************************
    RECOMMENDATION:
    Install the patch.
    ****************************************************************
    

Problem conclusion

  • Issue fixed. Added a check to see if there is a
    session-available, before trying to access session-specific
    error info. Code-fix committed & patch provided as part of the
    APAR # JR35970.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR35970

  • Reported component name

    WIS DATASTAGE

  • Reported component ID

    5724Q36DS

  • Reported release

    801

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-03-18

  • Closed date

    2010-03-29

  • Last modified date

    2010-03-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WIS DATASTAGE

  • Fixed component ID

    5724Q36DS

Applicable component levels

  • R801 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"IBM InfoSphere DataStage"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]