  • Db2 connector Stage 8.1 rollup patch 2. Target table contains a
    char(1) column. Bulk load is used with lob or XML
    column(s)=false.
    
    Control character 0x00 is load (transfomer is used setting value
    as char(0). This character is load as a space, 0x20.
    

Local fix

  • Use insert.
    

Problem summary

  • ****************************************************************
    
    USERS AFFECTED:
    The issue occurs when using UDB LOAD stage
    ****************************************************************
    PROBLEM DESCRIPTION:
    The UDB LOAD stage does not correctly handle input data
    containing 0x0 characters.
    ****************************************************************
    RECOMMENDATION:
    Install patch_JR35725
    ****************************************************************
    

Problem conclusion

  • The issue has been fixed by patch_JR35725. DB2 UDB Load now
    handles the 0x00 character in 'Char' field correctly.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR35725

  • Reported component name

    WIS DATASTAGE

  • Reported component ID

    5724Q36DS

  • Reported release

    810

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-03-01

  • Closed date

    2011-05-26

  • Last modified date

    2011-05-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WIS DATASTAGE

  • Fixed component ID

    5724Q36DS

Applicable component levels

  • R810 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"InfoSphere DataStage"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.1","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
11 October 2021