Error description
A job which contains a sequential file stage may intermittently fail, and cause a core dump, if one of that stage's input columns contains multi-byte characters and has a length greater than 128 bytes.
Local fix
Enable 'Allow per-column mapping' in the sequential file stage.
Problem summary
**************************************************************** USERS AFFECTED: DataStage 7.5.3 users that have NLS enabled and import multi-byte sequential data. **************************************************************** PROBLEM DESCRIPTION: A job reading delimited data in a sequential file stage may fail and cause a core dump if: (a) NLS is enabled, and (b) a column's length is greater than 128 bytes, and (c) the input data for that column contains multi-byte characters. **************************************************************** RECOMMENDATION: Apply the patch for JR35363. ****************************************************************
Problem conclusion
The sequential file stage implementation was writing beyond a column's allocated buffer during multi-byte processing. This was corrected by adding additional, multi-byte specific, checks that can trigger buffer reallocation.
Temporary fix
Enable 'Allow per-column mapping' in the sequential file stage.
Comments
APAR Information
APAR number
JR35363
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
753
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-01-14
Closed date
2011-05-05
Last modified date
2011-05-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
R753 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"InfoSphere DataStage"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.3","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
12 October 2021