IBM Support

JR35120: COMPILE ERRORS WHEN LARGE NUMBER OF PARAMETER SETS USED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Compile errors such as below when jobs use large
    parameter set - in this case 1100 entries:
    
    Activity Code_PJD_PBS_Payable_To_Cd_Extr: Expression
    "pCOL_POS_1" -
    Variable 'WHS_PARAM_SET_EXTR.PAYABLE_TO_CD_COL_1' not defined
    Finished at: 11/20/2009 5:50:00 PM
    

Local fix

  • This fix is included in 8.0.1 fixpack 3
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    DataStage Developers using Job Sequences
    ****************************************************************
    PROBLEM DESCRIPTION:
    Job sequence compilation intermittently fails.
    Failure occurred compiling job sequences with many JobActivities
    that used a very large ParameterSet, 1100 entries.
    It appears that this led to a memory allocation failure with
    unpredictable results.
    ****************************************************************
    RECOMMENDATION:
    Customers that experience job sequence compilation failures for
    job sequnces that use large parameter sets should install this
    patch.
    ****************************************************************
    

Problem conclusion

  • Job Sequence compilation was optimized to reduce memory required
    for this case and this resolved the problem.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR35120

  • Reported component name

    WIS DATASTAGE

  • Reported component ID

    5724Q36DS

  • Reported release

    802

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-12-15

  • Closed date

    2009-12-23

  • Last modified date

    2010-12-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • CLIENT
    

Fix information

  • Fixed component name

    WIS DATASTAGE

  • Fixed component ID

    5724Q36DS

Applicable component levels

  • R802 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"InfoSphere DataStage"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"802","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 October 2021