Error description

  • WSID/RTI jobs log the following message in their log file:  (DSS
    ocketNotify): OpenSocket returned 39"). This did not occur at
    release 7.5.1.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    Anyone using a DataStage job without ISD stages as a provider in
    an ISD Operation.
    ****************************************************************
    PROBLEM DESCRIPTION:
    If a DataStage job does not have ISD stages, then it is
    incorrectly configured by ISD to send two termination messages
    to ISD when the job ends.  The second message cannot be sent,
    however, because the first message causes ISD to close the
    receiving socket. Thus the OpenSocket error.
    ****************************************************************
    RECOMMENDATION:
    Install Information Server 8.1 Fix Pack 1.
    ****************************************************************
    

Problem conclusion

  • Fix made for Information Server 8.1 Fix Pack 1 to properly
    configure DataStage jobs without ISD stages to only send a
    single termination message when the job ends. This will prevent
    the OpenSocket error from happening.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR33910

  • Reported component name

    WIS DATASTAGE

  • Reported component ID

    5724Q36DS

  • Reported release

    810

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-08-05

  • Closed date

    2009-09-28

  • Last modified date

    2009-09-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WIS DATASTAGE

  • Fixed component ID

    5724Q36DS

Applicable component levels

  • R810 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"IBM InfoSphere DataStage"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
28 September 2009