Error description

  • When a check pointed Job Sequence restarts with new parameters,
    job throws a "The current job run does not have the same
    parameters as its checkpoint record" error.
    

Local fix

  • This fix is included in 8.0.1 fixpack 3
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    Server
    ****************************************************************
    PROBLEM DESCRIPTION:
    When restarting a sequence which in turn contains other
    sequences, the reset code can cause a problem which manifests
    itself as an error indicating the child sequence has not
    startedafter the timeout period. In reality it has run to
    completion.
    ****************************************************************
    RECOMMENDATION:
    Only way to resolve the problem is to apply the patch. The
    problem is however performance related.
    This fix is included in 8.1 FP1.
    ****************************************************************
    

Problem conclusion

  • Modified code to handle auto reset of a sequence by treating it
    correctly as two events. RESET and RUN.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR33784

  • Reported component name

    WIS DATASTAGE

  • Reported component ID

    5724Q36DS

  • Reported release

    752

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-07-23

  • Closed date

    2009-08-20

  • Last modified date

    2010-12-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • SERVER
    

Fix information

  • Fixed component name

    WIS DATASTAGE

  • Fixed component ID

    5724Q36DS

Applicable component levels

  • R752 PSY

       UP

  • R753 PSN

       UP

  • R801 PSN

       UP

  • R810 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"IBM InfoSphere DataStage"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.2","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
09 December 2010