Error description
To enable the SELECT of SMALLINT column which is mapped to remote INT. Based on those fix, SELECT SMALLINT from remote INT in Teradata Wrapper behaves as following. 1) If the remote INT value falls in the range of SMALLINT, [-32768,32767], we can get the correct result. 2) If the INT value is out of this range, following error message will be reported. SQL0413N Overflow occurred during numeric data type conversion. SQLSTATE=22003
Local fix
Problem summary
Users affected: Users of the Teradata wrapper in InfoSphere Federation Server Problem description and summary: See error description.
Problem conclusion
Problem was first fixed in Version 9.5 FixPak 5 (s091123 ). This fix should be applied on the federation server.
Temporary fix
Comments
APAR Information
APAR number
JR32766
Reported component name
TERADATA WRAPPE
Reported component ID
5724N9709
Reported release
950
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-04-22
Closed date
2009-12-22
Last modified date
2009-12-22
APAR is sysrouted FROM one or more of the following:
JR32764
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TERADATA WRAPPE
Fixed component ID
5724N9709
Applicable component levels
R950 PSN
UP
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCAVPS","label":"Data Sources and Wrappers - Teradata"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.5","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
22 December 2009