IBM Support

JR31954: ISSUE WITH I/P LINK ORDER TO THE LOOKUP STAGE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The problem is that originally the stream input had to be laid
    down first and was thus first in the list of links. However it
    is now possible to lay down the reference link first. Just
    convert the first input link to a reference link and lay down a
    new stream link.
    
    
    
    The problem also manifests itself as incorrect information in
    the director monitor, which interestingly does not differentiate
    between primary and reference lookup irrespective of the order
    the job is assembled.
    

Local fix

  • This fix is included in 8.0.1 fix pack 3
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    Jobs using PxLookup stage
    ****************************************************************
    PROBLEM DESCRIPTION:
    Depending on the order in which PxLookup stage inputs llinks
    arecreated the reported row counts for reference links may be
      incorrectly reported. The first link was incorrectly assumed
    to be the stream input and the stream input's row count is used
    forall reference links.
    ****************************************************************
    RECOMMENDATION:
    apply patch and re-compile jobs that exhibit the problem.
    This change is included in 8.1 FP1
    ****************************************************************
    

Problem conclusion

  • Changed Job compiler to ensure that stream input is first input.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR31954

  • Reported component name

    WIS DATASTAGE

  • Reported component ID

    5724Q36DS

  • Reported release

    752

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-02-09

  • Closed date

    2009-04-20

  • Last modified date

    2010-12-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WIS DATASTAGE

  • Fixed component ID

    5724Q36DS

Applicable component levels

  • R752 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"IBM InfoSphere DataStage"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.2","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]